{"product_id":"gr-5l-glass-reactor","title":"GR-5L Glass Reactor","description":"\u003cp data-start=\"38\" data-end=\"354\"\u003eThe \u003cstrong data-start=\"42\" data-end=\"65\"\u003eGR-5L Glass Reactor\u003c\/strong\u003e is a compact jacketed laboratory reactor designed for chemical synthesis, mixing, distillation, and temperature-controlled reaction experiments. With a \u003cstrong data-start=\"218\" data-end=\"247\"\u003e5-liter reaction capacity\u003c\/strong\u003e, this reactor is suitable for small-scale laboratory research, pilot experiments, and process development.\u003c\/p\u003e\n\u003cp data-start=\"356\" data-end=\"694\"\u003eConstructed from \u003cstrong data-start=\"373\" data-end=\"404\"\u003ehigh borosilicate glass 3.3\u003c\/strong\u003e, the reactor provides excellent chemical resistance, high transparency for visual observation, and strong thermal stability. The \u003cstrong data-start=\"534\" data-end=\"566\"\u003edouble-layer jacketed design\u003c\/strong\u003e allows circulating heating or cooling fluids to pass through the jacket, enabling precise temperature control during reactions.\u003c\/p\u003e\n\u003cp data-start=\"696\" data-end=\"1019\"\u003eThe reactor can operate under \u003cstrong data-start=\"726\" data-end=\"771\"\u003evacuum or atmospheric pressure conditions\u003c\/strong\u003e, making it suitable for sensitive reactions that require controlled pressure environments. The \u003cstrong data-start=\"867\" data-end=\"907\"\u003efrequency-controlled stirring system\u003c\/strong\u003e ensures stable mixing performance and allows precise speed adjustment for materials with different viscosities.\u003c\/p\u003e\n\u003cp data-start=\"1021\" data-end=\"1266\"\u003eThe stirring paddle features a \u003cstrong data-start=\"1052\" data-end=\"1094\"\u003estainless steel core with PTFE coating\u003c\/strong\u003e, providing excellent chemical compatibility and durability. The stainless steel frame structure offers strong mechanical stability and easy movement with lockable casters.\u003c\/p\u003e\n\u003cp data-start=\"1268\" data-end=\"1413\"\u003eThis reactor system is widely used in \u003cstrong data-start=\"1306\" data-end=\"1412\"\u003echemical laboratories, pharmaceutical research, material synthesis, and academic research environments\u003c\/strong\u003e.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1jadrcs\" data-start=\"1438\" data-end=\"1455\"\u003eReactor System\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1457\" data-end=\"2064\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1457\" data-end=\"1486\"\u003e\n\u003ctr data-start=\"1457\" data-end=\"1486\"\u003e\n\u003cth data-start=\"1457\" data-end=\"1469\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1469\" data-end=\"1486\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1517\" data-end=\"2064\"\u003e\n\u003ctr data-start=\"1517\" data-end=\"1534\"\u003e\n\u003ctd data-start=\"1517\" data-end=\"1525\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1525\" data-end=\"1534\" data-col-size=\"md\"\u003eGR-5L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1535\" data-end=\"1559\"\u003e\n\u003ctd data-start=\"1535\" data-end=\"1552\" data-col-size=\"sm\"\u003eReactor Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1552\" data-end=\"1559\"\u003e5 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1560\" data-end=\"1583\"\u003e\n\u003ctd data-start=\"1560\" data-end=\"1576\" data-col-size=\"sm\"\u003eJacket Volume\u003c\/td\u003e\n\u003ctd data-start=\"1576\" data-end=\"1583\" data-col-size=\"md\"\u003e2 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1584\" data-end=\"1614\"\u003e\n\u003ctd data-start=\"1584\" data-end=\"1604\" data-col-size=\"sm\"\u003eCondensation Area\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1604\" data-end=\"1614\"\u003e0.3 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1615\" data-end=\"1646\"\u003e\n\u003ctd data-start=\"1615\" data-end=\"1637\" data-col-size=\"sm\"\u003eFeeding Tank Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1637\" data-end=\"1646\"\u003e0.5 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1647\" data-end=\"1677\"\u003e\n\u003ctd data-start=\"1647\" data-end=\"1670\" data-col-size=\"sm\"\u003eRecovery Tank Volume\u003c\/td\u003e\n\u003ctd data-start=\"1670\" data-end=\"1677\" data-col-size=\"md\"\u003e3 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1678\" data-end=\"1726\"\u003e\n\u003ctd data-start=\"1678\" data-end=\"1695\" data-col-size=\"sm\"\u003eGlass Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1695\" data-end=\"1726\"\u003eHigh borosilicate glass 3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1727\" data-end=\"1766\"\u003e\n\u003ctd data-start=\"1727\" data-end=\"1740\" data-col-size=\"sm\"\u003eMain Frame\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1740\" data-end=\"1766\"\u003eSUS304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1767\" data-end=\"1855\"\u003e\n\u003ctd data-start=\"1767\" data-end=\"1785\" data-col-size=\"sm\"\u003eStirring Paddle\u003c\/td\u003e\n\u003ctd data-start=\"1785\" data-end=\"1855\" data-col-size=\"md\"\u003eStainless steel core with PTFE coating (titanium option available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1856\" data-end=\"1919\"\u003e\n\u003ctd data-start=\"1856\" data-end=\"1877\" data-col-size=\"sm\"\u003eMixing Motor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1877\" data-end=\"1919\"\u003eStandard 120 W \/ Explosion-proof 180 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1920\" data-end=\"1960\"\u003e\n\u003ctd data-start=\"1920\" data-end=\"1939\" data-col-size=\"sm\"\u003eSpeed Regulation\u003c\/td\u003e\n\u003ctd data-start=\"1939\" data-end=\"1960\" data-col-size=\"md\"\u003eFrequency control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1961\" data-end=\"1990\"\u003e\n\u003ctd data-start=\"1961\" data-end=\"1975\" data-col-size=\"sm\"\u003eSpeed Range\u003c\/td\u003e\n\u003ctd data-start=\"1975\" data-end=\"1990\" data-col-size=\"md\"\u003e0 – 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1991\" data-end=\"2021\"\u003e\n\u003ctd data-start=\"1991\" data-end=\"2012\" data-col-size=\"sm\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd data-start=\"2012\" data-end=\"2021\" data-col-size=\"md\"\u003ePT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2022\" data-end=\"2064\"\u003e\n\u003ctd data-start=\"2022\" data-end=\"2053\" data-col-size=\"sm\"\u003eTemperature Display Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2053\" data-end=\"2064\" data-col-size=\"md\"\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2066\" data-end=\"2069\"\u003e\n\u003ch2 data-section-id=\"elin5b\" data-start=\"2071\" data-end=\"2092\"\u003eReactor Interfaces\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2094\" data-end=\"2530\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2094\" data-end=\"2123\"\u003e\n\u003ctr data-start=\"2094\" data-end=\"2123\"\u003e\n\u003cth data-start=\"2094\" data-end=\"2106\" data-col-size=\"sm\" class=\"\"\u003eInterface\u003c\/th\u003e\n\u003cth data-start=\"2106\" data-end=\"2123\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2154\" data-end=\"2530\"\u003e\n\u003ctr data-start=\"2154\" data-end=\"2197\"\u003e\n\u003ctd data-start=\"2154\" data-end=\"2178\" data-col-size=\"sm\"\u003eKettle Cover Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2178\" data-end=\"2197\" data-col-size=\"sm\"\u003e50# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2198\" data-end=\"2237\"\u003e\n\u003ctd data-start=\"2198\" data-end=\"2218\" data-col-size=\"sm\"\u003eImpeller Diameter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2218\" data-end=\"2237\"\u003e50# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2238\" data-end=\"2288\"\u003e\n\u003ctd data-start=\"2238\" data-end=\"2269\" data-col-size=\"sm\"\u003eTemperature Sensor Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2269\" data-end=\"2288\"\u003e24# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2289\" data-end=\"2335\"\u003e\n\u003ctd data-start=\"2289\" data-end=\"2312\" data-col-size=\"sm\"\u003eCondenser Connection\u003c\/td\u003e\n\u003ctd data-start=\"2312\" data-end=\"2335\" data-col-size=\"sm\"\u003e35# spherical joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2336\" data-end=\"2388\"\u003e\n\u003ctd data-start=\"2336\" data-end=\"2356\" data-col-size=\"sm\"\u003eLiquid Feed Inlet\u003c\/td\u003e\n\u003ctd data-start=\"2356\" data-end=\"2388\" data-col-size=\"sm\"\u003e24# standard ground joint ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2389\" data-end=\"2443\"\u003e\n\u003ctd data-start=\"2389\" data-end=\"2414\" data-col-size=\"sm\"\u003eFeeding Tank Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2414\" data-end=\"2443\"\u003e29# standard ground joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2444\" data-end=\"2470\"\u003e\n\u003ctd data-start=\"2444\" data-end=\"2463\" data-col-size=\"sm\"\u003eSolid Feed Inlet\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2463\" data-end=\"2470\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2471\" data-end=\"2530\"\u003e\n\u003ctd data-start=\"2471\" data-end=\"2504\" data-col-size=\"sm\"\u003eStainless Steel Hose Interface\u003c\/td\u003e\n\u003ctd data-start=\"2504\" data-end=\"2530\" data-col-size=\"sm\"\u003e½ inch external thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2532\" data-end=\"2535\"\u003e\n\u003ch2 data-section-id=\"14z1rqw\" data-start=\"2537\" data-end=\"2560\"\u003eOperating Conditions\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2562\" data-end=\"2925\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2562\" data-end=\"2591\"\u003e\n\u003ctr data-start=\"2562\" data-end=\"2591\"\u003e\n\u003cth data-start=\"2562\" data-end=\"2574\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2574\" data-end=\"2591\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2622\" data-end=\"2925\"\u003e\n\u003ctr data-start=\"2622\" data-end=\"2664\"\u003e\n\u003ctd data-start=\"2622\" data-end=\"2644\" data-col-size=\"sm\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2644\" data-end=\"2664\" data-col-size=\"sm\"\u003e-120 °C ~ 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2665\" data-end=\"2709\"\u003e\n\u003ctd data-start=\"2665\" data-end=\"2698\" data-col-size=\"sm\"\u003eMaximum Temperature Difference\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2698\" data-end=\"2709\"\u003e≤ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2710\" data-end=\"2747\"\u003e\n\u003ctd data-start=\"2710\" data-end=\"2729\" data-col-size=\"sm\"\u003eReactor Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2729\" data-end=\"2747\" data-col-size=\"sm\"\u003e-0.1 ~ 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2748\" data-end=\"2790\"\u003e\n\u003ctd data-start=\"2748\" data-end=\"2777\" data-col-size=\"sm\"\u003eJacket Pressure Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2777\" data-end=\"2790\"\u003e≤ 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2791\" data-end=\"2832\"\u003e\n\u003ctd data-start=\"2791\" data-end=\"2819\" data-col-size=\"sm\"\u003eVacuum Pressure Rise Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2819\" data-end=\"2832\"\u003e≤ 2 kPa\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2833\" data-end=\"2875\"\u003e\n\u003ctd data-start=\"2833\" data-end=\"2861\" data-col-size=\"sm\"\u003eTemperature Range (Water)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2861\" data-end=\"2875\"\u003eRT ~ 90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2876\" data-end=\"2925\"\u003e\n\u003ctd data-start=\"2876\" data-end=\"2910\" data-col-size=\"sm\"\u003eTemperature Range (Thermal Oil)\u003c\/td\u003e\n\u003ctd data-start=\"2910\" data-end=\"2925\" data-col-size=\"sm\"\u003eRT ~ 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2927\" data-end=\"2930\"\u003e\n\u003ch2 data-section-id=\"1rew726\" data-start=\"2932\" data-end=\"2958\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2960\" data-end=\"3140\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2960\" data-end=\"2989\"\u003e\n\u003ctr data-start=\"2960\" data-end=\"2989\"\u003e\n\u003cth data-start=\"2960\" data-end=\"2972\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2972\" data-end=\"2989\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3020\" data-end=\"3140\"\u003e\n\u003ctr data-start=\"3020\" data-end=\"3068\"\u003e\n\u003ctd data-start=\"3020\" data-end=\"3058\" data-col-size=\"sm\"\u003eDischarge Valve Installation Height\u003c\/td\u003e\n\u003ctd data-start=\"3058\" data-end=\"3068\" data-col-size=\"sm\"\u003e205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3069\" data-end=\"3113\"\u003e\n\u003ctd data-start=\"3069\" data-end=\"3090\" data-col-size=\"sm\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3090\" data-end=\"3113\" data-col-size=\"sm\"\u003e500 × 520 × 1510 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3114\" data-end=\"3140\"\u003e\n\u003ctd data-start=\"3114\" data-end=\"3131\" data-col-size=\"sm\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd data-start=\"3131\" data-end=\"3140\" data-col-size=\"sm\"\u003e60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3142\" data-end=\"3145\"\u003e\n\u003ch2 data-section-id=\"8uzq1k\" data-start=\"3147\" data-end=\"3174\"\u003eElectrical \u0026amp; Environment\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3176\" data-end=\"3349\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3176\" data-end=\"3205\"\u003e\n\u003ctr data-start=\"3176\" data-end=\"3205\"\u003e\n\u003cth data-start=\"3176\" data-end=\"3188\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"3188\" data-end=\"3205\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3236\" data-end=\"3349\"\u003e\n\u003ctr data-start=\"3236\" data-end=\"3278\"\u003e\n\u003ctd data-start=\"3236\" data-end=\"3251\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3251\" data-end=\"3278\" data-col-size=\"sm\"\u003e110V \/ 220V, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3279\" data-end=\"3316\"\u003e\n\u003ctd data-start=\"3279\" data-end=\"3303\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3303\" data-end=\"3316\" data-col-size=\"sm\"\u003e5 – 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3317\" data-end=\"3349\"\u003e\n\u003ctd data-start=\"3317\" data-end=\"3337\" data-col-size=\"sm\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3337\" data-end=\"3349\" data-col-size=\"sm\"\u003e≤ 65% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3356\" data-end=\"3371\"\u003e\u003c\/h2\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3356\" data-end=\"3371\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"3372\" data-end=\"3610\"\u003e\n\u003cli data-section-id=\"15f35fm\" data-start=\"3372\" data-end=\"3404\"\u003e\n\u003cp data-start=\"3374\" data-end=\"3404\"\u003eChemical synthesis reactions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uc5ar2\" data-start=\"3405\" data-end=\"3443\"\u003e\n\u003cp data-start=\"3407\" data-end=\"3443\"\u003eLaboratory distillation and reflux\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ww5znj\" data-start=\"3444\" data-end=\"3489\"\u003e\n\u003cp data-start=\"3446\" data-end=\"3489\"\u003ePharmaceutical and biotechnology research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7xad9r\" data-start=\"3490\" data-end=\"3533\"\u003e\n\u003cp data-start=\"3492\" data-end=\"3533\"\u003eMaterial synthesis and catalyst testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yhujph\" data-start=\"3534\" data-end=\"3574\"\u003e\n\u003cp data-start=\"3536\" data-end=\"3574\"\u003ePolymer and nanomaterial development\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14qbqm4\" data-start=\"3575\" data-end=\"3610\"\u003e\n\u003cp data-start=\"3577\" data-end=\"3610\"\u003eAcademic laboratory experiments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Equipment Solutions","offers":[{"title":"Default Title","offer_id":44161300103254,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0711\/1586\/6198\/files\/GR-5LGlassReactor.1.jpg?v=1773332991","url":"https:\/\/atlasequipsolu.com\/products\/gr-5l-glass-reactor","provider":"Atlas Equipment Solutions","version":"1.0","type":"link"}