{"product_id":"gr-200l-glass-reactor","title":"GR-200L Glass Reactor","description":"\u003cp data-start=\"56\" data-end=\"421\"\u003eThe \u003cstrong data-start=\"60\" data-end=\"101\"\u003eGR-200L Double Jacketed Glass Reactor\u003c\/strong\u003e is a large-capacity laboratory and pilot-scale reaction system designed for chemical synthesis, mixing, distillation, and material processing. The reactor vessel is constructed from \u003cstrong data-start=\"284\" data-end=\"315\"\u003ehigh borosilicate glass 3.3\u003c\/strong\u003e, offering excellent chemical resistance, high transparency for observation, and strong thermal stability.\u003c\/p\u003e\n\u003cp data-start=\"423\" data-end=\"744\"\u003eThe \u003cstrong data-start=\"427\" data-end=\"459\"\u003edouble-layer jacketed design\u003c\/strong\u003e allows heat transfer fluid to circulate through the jacket while the reaction occurs in the inner vessel. By connecting external heating or cooling equipment, such as circulators or chillers, the reactor can maintain precise temperature control for both heating and cooling reactions.\u003c\/p\u003e\n\u003cp data-start=\"746\" data-end=\"1157\"\u003eThe system supports operation under \u003cstrong data-start=\"782\" data-end=\"827\"\u003evacuum or atmospheric pressure conditions\u003c\/strong\u003e, enabling flexible experimental environments for sensitive reactions. The reactor is equipped with \u003cstrong data-start=\"927\" data-end=\"960\"\u003efrequency-controlled stirring\u003c\/strong\u003e, allowing stable mixing for materials with different viscosities. The stirring paddle is designed with a \u003cstrong data-start=\"1066\" data-end=\"1107\"\u003estainless steel core and PTFE coating\u003c\/strong\u003e, providing durability and chemical compatibility.\u003c\/p\u003e\n\u003cp data-start=\"1159\" data-end=\"1374\"\u003eWith its large capacity and robust construction, this glass reactor is widely used in \u003cstrong data-start=\"1245\" data-end=\"1373\"\u003echemical synthesis, pharmaceutical research, material science, pilot-scale experiments, and process development laboratories\u003c\/strong\u003e.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1l2cjfj\" data-start=\"1400\" data-end=\"1418\"\u003eReactor System\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1420\" data-end=\"2000\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1420\" data-end=\"1449\"\u003e\n\u003ctr data-start=\"1420\" data-end=\"1449\"\u003e\n\u003cth data-start=\"1420\" data-end=\"1432\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1432\" data-end=\"1449\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1480\" data-end=\"2000\"\u003e\n\u003ctr data-start=\"1480\" data-end=\"1499\"\u003e\n\u003ctd data-start=\"1480\" data-end=\"1488\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1488\" data-end=\"1499\"\u003eGR-200L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1500\" data-end=\"1526\"\u003e\n\u003ctd data-start=\"1500\" data-end=\"1517\" data-col-size=\"sm\"\u003eReactor Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1517\" data-end=\"1526\"\u003e200 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1527\" data-end=\"1551\"\u003e\n\u003ctd data-start=\"1527\" data-end=\"1543\" data-col-size=\"sm\"\u003eJacket Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1543\" data-end=\"1551\"\u003e60 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1552\" data-end=\"1581\"\u003e\n\u003ctd data-start=\"1552\" data-end=\"1574\" data-col-size=\"sm\"\u003eFeeding Tank Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1574\" data-end=\"1581\"\u003e2 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1582\" data-end=\"1613\"\u003e\n\u003ctd data-start=\"1582\" data-end=\"1605\" data-col-size=\"sm\"\u003eRecovery Tank Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1605\" data-end=\"1613\"\u003e20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1614\" data-end=\"1662\"\u003e\n\u003ctd data-start=\"1614\" data-end=\"1631\" data-col-size=\"sm\"\u003eGlass Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1631\" data-end=\"1662\"\u003eHigh borosilicate glass 3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1663\" data-end=\"1702\"\u003e\n\u003ctd data-start=\"1663\" data-end=\"1676\" data-col-size=\"sm\"\u003eMain Frame\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1676\" data-end=\"1702\"\u003eSUS304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1703\" data-end=\"1791\"\u003e\n\u003ctd data-start=\"1703\" data-end=\"1721\" data-col-size=\"sm\"\u003eStirring Paddle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1721\" data-end=\"1791\"\u003eStainless steel core with PTFE coating (titanium option available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1792\" data-end=\"1855\"\u003e\n\u003ctd data-start=\"1792\" data-end=\"1813\" data-col-size=\"sm\"\u003eMixing Motor Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1813\" data-end=\"1855\"\u003eStandard 750 W \/ Explosion-proof 750 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1856\" data-end=\"1896\"\u003e\n\u003ctd data-start=\"1856\" data-end=\"1875\" data-col-size=\"sm\"\u003eSpeed Regulation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1875\" data-end=\"1896\"\u003eFrequency control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1897\" data-end=\"1926\"\u003e\n\u003ctd data-start=\"1897\" data-end=\"1911\" data-col-size=\"sm\"\u003eSpeed Range\u003c\/td\u003e\n\u003ctd data-start=\"1911\" data-end=\"1926\" data-col-size=\"md\"\u003e0 – 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1927\" data-end=\"1957\"\u003e\n\u003ctd data-start=\"1927\" data-end=\"1948\" data-col-size=\"sm\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd data-start=\"1948\" data-end=\"1957\" data-col-size=\"md\"\u003ePT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1958\" data-end=\"2000\"\u003e\n\u003ctd data-start=\"1958\" data-end=\"1989\" data-col-size=\"sm\"\u003eTemperature Display Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1989\" data-end=\"2000\"\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2002\" data-end=\"2005\"\u003e\n\u003ch3 data-section-id=\"zl8bbg\" data-start=\"2007\" data-end=\"2029\"\u003eReactor Interfaces\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2031\" data-end=\"2480\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2031\" data-end=\"2060\"\u003e\n\u003ctr data-start=\"2031\" data-end=\"2060\"\u003e\n\u003cth data-start=\"2031\" data-end=\"2043\" data-col-size=\"sm\" class=\"\"\u003eInterface\u003c\/th\u003e\n\u003cth data-start=\"2043\" data-end=\"2060\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2091\" data-end=\"2480\"\u003e\n\u003ctr data-start=\"2091\" data-end=\"2134\"\u003e\n\u003ctd data-start=\"2091\" data-end=\"2115\" data-col-size=\"sm\"\u003eKettle Cover Diameter\u003c\/td\u003e\n\u003ctd data-start=\"2115\" data-end=\"2134\" data-col-size=\"sm\"\u003e60# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2135\" data-end=\"2174\"\u003e\n\u003ctd data-start=\"2135\" data-end=\"2155\" data-col-size=\"sm\"\u003eImpeller Diameter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2155\" data-end=\"2174\"\u003e60# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2175\" data-end=\"2225\"\u003e\n\u003ctd data-start=\"2175\" data-end=\"2206\" data-col-size=\"sm\"\u003eTemperature Sensor Interface\u003c\/td\u003e\n\u003ctd data-start=\"2206\" data-end=\"2225\" data-col-size=\"sm\"\u003e40# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2226\" data-end=\"2272\"\u003e\n\u003ctd data-start=\"2226\" data-end=\"2249\" data-col-size=\"sm\"\u003eCondenser Connection\u003c\/td\u003e\n\u003ctd data-start=\"2249\" data-end=\"2272\" data-col-size=\"sm\"\u003e50# spherical joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2273\" data-end=\"2325\"\u003e\n\u003ctd data-start=\"2273\" data-end=\"2293\" data-col-size=\"sm\"\u003eLiquid Feed Inlet\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2293\" data-end=\"2325\"\u003e34# standard ground joint ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2326\" data-end=\"2380\"\u003e\n\u003ctd data-start=\"2326\" data-end=\"2351\" data-col-size=\"sm\"\u003eFeeding Tank Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2351\" data-end=\"2380\"\u003e40# standard ground joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2381\" data-end=\"2420\"\u003e\n\u003ctd data-start=\"2381\" data-end=\"2400\" data-col-size=\"sm\"\u003eSolid Feed Inlet\u003c\/td\u003e\n\u003ctd data-start=\"2400\" data-end=\"2420\" data-col-size=\"sm\"\u003e120# flange type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2421\" data-end=\"2480\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2454\" data-col-size=\"sm\"\u003eStainless Steel Hose Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2454\" data-end=\"2480\"\u003e½ inch external thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2482\" data-end=\"2485\"\u003e\n\u003ch3 data-section-id=\"106482j\" data-start=\"2487\" data-end=\"2511\"\u003eOperating Conditions\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2513\" data-end=\"2876\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2513\" data-end=\"2542\"\u003e\n\u003ctr data-start=\"2513\" data-end=\"2542\"\u003e\n\u003cth data-start=\"2513\" data-end=\"2525\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2525\" data-end=\"2542\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2573\" data-end=\"2876\"\u003e\n\u003ctr data-start=\"2573\" data-end=\"2615\"\u003e\n\u003ctd data-start=\"2573\" data-end=\"2595\" data-col-size=\"sm\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2595\" data-end=\"2615\" data-col-size=\"sm\"\u003e-120 °C ~ 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2616\" data-end=\"2660\"\u003e\n\u003ctd data-start=\"2616\" data-end=\"2649\" data-col-size=\"sm\"\u003eMaximum Temperature Difference\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2649\" data-end=\"2660\"\u003e≤ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2661\" data-end=\"2698\"\u003e\n\u003ctd data-start=\"2661\" data-end=\"2680\" data-col-size=\"sm\"\u003eReactor Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2680\" data-end=\"2698\"\u003e-0.1 ~ 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2699\" data-end=\"2741\"\u003e\n\u003ctd data-start=\"2699\" data-end=\"2728\" data-col-size=\"sm\"\u003eJacket Pressure Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2728\" data-end=\"2741\"\u003e≤ 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2742\" data-end=\"2783\"\u003e\n\u003ctd data-start=\"2742\" data-end=\"2770\" data-col-size=\"sm\"\u003eVacuum Pressure Rise Rate\u003c\/td\u003e\n\u003ctd data-start=\"2770\" data-end=\"2783\" data-col-size=\"sm\"\u003e≤ 2 kPa\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2784\" data-end=\"2826\"\u003e\n\u003ctd data-start=\"2784\" data-end=\"2812\" data-col-size=\"sm\"\u003eTemperature Range (Water)\u003c\/td\u003e\n\u003ctd data-start=\"2812\" data-end=\"2826\" data-col-size=\"sm\"\u003eRT ~ 90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2827\" data-end=\"2876\"\u003e\n\u003ctd data-start=\"2827\" data-end=\"2861\" data-col-size=\"sm\"\u003eTemperature Range (Thermal Oil)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2861\" data-end=\"2876\"\u003eRT ~ 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2878\" data-end=\"2881\"\u003e\n\u003ch3 data-section-id=\"16isa0t\" data-start=\"2883\" data-end=\"2910\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2912\" data-end=\"3095\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2912\" data-end=\"2941\"\u003e\n\u003ctr data-start=\"2912\" data-end=\"2941\"\u003e\n\u003cth data-start=\"2912\" data-end=\"2924\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2924\" data-end=\"2941\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2972\" data-end=\"3095\"\u003e\n\u003ctr data-start=\"2972\" data-end=\"3020\"\u003e\n\u003ctd data-start=\"2972\" data-end=\"3010\" data-col-size=\"sm\"\u003eDischarge Valve Installation Height\u003c\/td\u003e\n\u003ctd data-start=\"3010\" data-end=\"3020\" data-col-size=\"sm\"\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3021\" data-end=\"3067\"\u003e\n\u003ctd data-start=\"3021\" data-end=\"3042\" data-col-size=\"sm\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3042\" data-end=\"3067\"\u003e1140 × 1240 × 3100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3068\" data-end=\"3095\"\u003e\n\u003ctd data-start=\"3068\" data-end=\"3085\" data-col-size=\"sm\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3095\" data-col-size=\"sm\"\u003e190 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3097\" data-end=\"3100\"\u003e\n\u003ch3 data-section-id=\"1f0c2m3\" data-start=\"3102\" data-end=\"3130\"\u003eElectrical \u0026amp; Environment\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3132\" data-end=\"3305\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3132\" data-end=\"3161\"\u003e\n\u003ctr data-start=\"3132\" data-end=\"3161\"\u003e\n\u003cth data-start=\"3132\" data-end=\"3144\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"3144\" data-end=\"3161\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3192\" data-end=\"3305\"\u003e\n\u003ctr data-start=\"3192\" data-end=\"3234\"\u003e\n\u003ctd data-start=\"3192\" data-end=\"3207\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3207\" data-end=\"3234\" data-col-size=\"sm\"\u003e110V \/ 220V, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3235\" data-end=\"3272\"\u003e\n\u003ctd data-start=\"3235\" data-end=\"3259\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3259\" data-end=\"3272\"\u003e5 – 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3273\" data-end=\"3305\"\u003e\n\u003ctd data-start=\"3273\" data-end=\"3293\" data-col-size=\"sm\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3293\" data-end=\"3305\" data-col-size=\"sm\"\u003e≤ 65% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3312\" data-end=\"3327\"\u003e\u003c\/h2\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3312\" data-end=\"3327\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"3328\" data-end=\"3637\"\u003e\n\u003cli data-section-id=\"382akn\" data-start=\"3328\" data-end=\"3373\"\u003e\n\u003cp data-start=\"3330\" data-end=\"3373\"\u003eChemical synthesis and reaction processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dv7cz2\" data-start=\"3374\" data-end=\"3417\"\u003e\n\u003cp data-start=\"3376\" data-end=\"3417\"\u003ePharmaceutical research and development\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l1iw44\" data-start=\"3418\" data-end=\"3453\"\u003e\n\u003cp data-start=\"3420\" data-end=\"3453\"\u003ePilot-scale chemical production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hrw8f2\" data-start=\"3454\" data-end=\"3498\"\u003e\n\u003cp data-start=\"3456\" data-end=\"3498\"\u003ePolymer and material science experiments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1omi2qp\" data-start=\"3499\" data-end=\"3543\"\u003e\n\u003cp data-start=\"3501\" data-end=\"3543\"\u003eMixing and reaction of viscous materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fq6dkh\" data-start=\"3544\" data-end=\"3588\"\u003e\n\u003cp data-start=\"3546\" data-end=\"3588\"\u003eDistillation and concentration processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"36lhuh\" data-start=\"3589\" data-end=\"3637\"\u003e\n\u003cp data-start=\"3591\" data-end=\"3637\"\u003eProcess development and scale-up experiments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Equipment Solutions","offers":[{"title":"Default Title","offer_id":44161216610390,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0711\/1586\/6198\/files\/GR-200LGlassReactor.1_f445e233-54bd-4fb1-9bdb-4e841ccd4957.jpg?v=1773848799","url":"https:\/\/atlasequipsolu.com\/products\/gr-200l-glass-reactor","provider":"Atlas Equipment Solutions","version":"1.0","type":"link"}